Auto-Translate
When researching lighting and especially grow lights, you will inevitably stumble across some common metrics and abbreviations. Some of them are more advanced while others are pretty common. Assuming you aren't an engineer or a horticulture scientist, we'll briefly explain the most common terms used in lighting and plant grow lights.
CCT: Correlated Color Temperature (Kelvin)
Correlated color temperature (CCT) refers to the color appearance of a light source and is measured in Kelvin (K). In other words, the CCT describes how "warm" or "cool" a light appears. E.g. a lower CCT like 2700K describes a warm, yellowish light. A higher CCT such as 6500K describes a cool, bluish light.
The CCT is an important factor in plant lighting as it can influence a plant’s properties during various growth stages such as flowering and fruit production, leaf size and thickness, and the overall plant shape and structure.
The sun's CCT varies throughout the day, ranging from warm reddish-orange light (2000-3000K) at sunrise and sunset, to cooler white light (5500-6500K) at midday. This natural cycle occurs due to changes in the sun's position and the amount of atmospheric gasses its light travels through.
Coverage (Heatmaps)
Coverage defines the grow light’s ability to illuminate an area effectively. It is often compared using heatmaps (also called PAR maps, PPFD maps or PPFD footprint charts) that contain different measurements across an area at a certain height of the grow light. How evenly the light is spread across the area is described by its uniformity.
CU: Coefficient of Utilization (%)
The coefficient of utilization (CU) tells how much of a grow light's output actually lands on your grow area: the usable PPF divided by the PPF the lamp emits according to its spec sheet, in percent. The rest misses your plants and is lost on walls, floor and aisles.
The CU is not a property of the lamp alone, but of your whole setup. It depends on the beam angle of the lamp, how high it hangs, the size of the grow area and how well the walls around it reflect light. The higher a lamp hangs, the more of its light usually misses the plants, while the reflective walls of a grow tent send a part of it back.
DLI: Daily Light Integral (mol/m²/d)
The Daily Light Integral (DLI) describes the total amount of photosynthetically active radiation (PAR) your plant receives over the course of a day. It combines light intensity (PPFD) with the duration of exposure (photoperiod) and is measured in mol/m²/d.
The factor 0.0036 converts the units: an hour has 3600 seconds and a mol is a million µmol.
There are two ways to determine DLI:
1. Projected DLI (instant)
If the light intensity stays constant, you can calculate the expected DLI from the PPFD and the number of hours your plant
receives light. This is particularly useful when you control the lighting with a grow light.
Our free Photone app lets you enter the lighting duration and instantly calculates the projected DLI from your measured PPFD. Alternatively, you can use the PPFD to DLI calculator.
2. Actual DLI (24-hour measurement)
If light intensity changes throughout the day, you need to measure it over the full 24-hour period. A light meter
with a logging function can continuously record PPFD and integrate the measurements into a single DLI value. Use this when growing with natural
sun light.
You can use our free Photone app for this, or a dedicated device such as the DLI-500 by Apogee Instruments.
To learn more, see our detailed article about DLI.
eDLI: Extended Daily Light Integral
ePAR: Extended Photosynthetically Active Radiation
ePPFD: Extended Photosynthetic Photon Flux Density
Far-red light
Far-red photons are light, roughly 700–750 nm, sitting just before near-infrared and barely visible to the eye. On its own it barely powers photosynthesis, but it has two interesting effects on plants:
First, when mixed with normal/visible light it gives photosynthesis a helpful boost. Second, and more interestingly, plants use far-red light like a built-in sensor for their surroundings: because leaves absorb red light but let far-red pass through and bounce off, a lot of far-red means other plants are nearby — either shading it from above or crowding it from the side. That signal tells the plant to stretch taller and race for sunlight.
Illuminance (Lux or Foot-candle)
Illuminance describes how much of human-visible light hits a surface. In scientific terms: the total luminous flux incident on a surface, per unit area.
Illuminance is measured in lux (lx) or foot-candle (fc). Lux is the metric unit and defined as lumen per m² while foot-candle is the imperial unit defined as lumen per ft². 1 fc is equal to 10.76 lx.
ℹ️ Note that the illuminance will change depending on how close you get to a lamp, while the luminous flux only changes when changing the power (e.g. by dimming) of the lamp.
☝️ Illuminance is only relevant when measuring light for humans. The corresponding measure for plants is PPFD. To learn more, we recommend our detailed article.
IR: Infrared
Infrared (IR) light describes electromagnetic radiation in wavelengths between 700 nm and 1 mm. IR radiation can be felt as heat (e.g. when you're exposed to sunlight). Some plants may also use near infrared (NIR) in the range of 700 to 1400 nm to grow. IR light cannot be seen by the human eye.
Light Intensity
In physics, intensity describes energy per unit area. Light intensity means how much light hits on a given area. DLI, eDLI, PPFD, ePPFD and illuminance are all measurements of light intensity.
Lost Light (µmol/s)
Lost light is the part of a grow light's PPF that misses your grow area: it lands on walls, floor and aisles instead of your plants. It is what's left of the rated PPF of the lamp after subtracting the usable PPF, in µmol/s.
You lose less light if the lamp hangs lower, if the walls around the grow area reflect light back onto it (like in a grow tent) and if the area the lamp illuminates matches your grow area.
Luminous Flux (Lumen)
The total light output of a light source is described as luminous flux or luminous power. It is measured in lumen (lm).
Note that the illuminance will change depending on how close you get to a lamp, while the luminous flux only changes when changing the power (e.g. by dimming) of the lamp.
Lumen is a measurement for humans and light is valued as it is perceived by the human eye. The synonym in lighting for plants would be PPF. To learn more, we recommend our detailed article on the difference between Lumen and PPFD.
McCree Curve
The McCree curve (🌱 in the chart below) represents the average photosynthetic response of plants to different wavelengths of light, based on research conducted by Dr. Keith McCree in the 1970s. While it shows that plants generally respond more efficiently to red and blue light, the actual photosynthetic response varies among plant species, growth stages, and environmental conditions.
Due to this variability and practical measurement considerations, the scientific community widely adopted PAR (Photosynthetically Active Radiation) as a standard metric. PAR simply counts all photons between 400–700 nm equally, providing a more straightforward and universally applicable measure of light available for photosynthesis.
Min/Avg: Minimum to Average PPFD
The min/avg ratio compares the darkest spot of your grow area with its average PPFD, as a ratio between 0 and 1. It tells how much light the plant that gets the least still gets compared to the others. Some manufacturers call it homogeneity.
Let's look at some example light footprints and compare their min/avg ratios:
The footprint above has a weak min/avg ratio of 0.37 (181 ÷ 487).
This footprint looks better and has a min/avg ratio of 0.90 (532 ÷ 590).
ℹ️ Unlike the uniformity, the min/avg ratio only looks at a single spot: one dark corner pulls it down, no matter how even the rest is. A value of 0.7 and above is acceptable, 0.8 and above good.
PAR: Photosynthetically Active Radiation
Plants (🌱) are sensitive to different wavelengths (i.e. colors) of light than humans (👁️). Since it is not exactly known how much of each
wavelength a given plant needs, the entire range from 400 to 700 nm is weighted equally when measuring light for plants. This range is called
photosynthetically active radiation (PAR) – the portion of light that plants can use for photosynthesis
A PAR meter measures the
photosynthetic photon flux density (PPFD) – in other words, the amount of light usable by plants that is hitting a leaf at that moment. A
lux meter, on the other hand, weights red and blue light much less strongly, because the human eye (👁️) is less sensitive in those areas. That’s
why you should always use a PAR meter when measuring light for plants. To learn more, we recommend our detailed
article.
Photon
A photon is a tiny particle of light — the smallest possible "packet" that light comes in. Each photon travels as a tiny electromagnetic wave, and the length of that wave — its wavelength — is what we perceive as color: shorter waves carry more energy and look bluish, longer waves carry less and look reddish. When a photon of the right wavelength strikes a plant, it can be captured by pigments like chlorophyll that power photosynthesis.
Now you know why we named our app "Photone" 😏
Photoperiod (h)
The photoperiod describes the duration of daily illumination received by a plant. It is commonly used to describe grow light schedules, meaning how many hours a day a grow light is turned on. This is why we measure the photoperiod in hours (h).
Photosynthesis
Photosynthesis is the process plants use to turn light, water, and carbon dioxide into oxygen and energy stored as sugar — which is how plants grow.
The light is captured by special pigments called chlorophylls found in the leaves. Chlorophyll absorbs mostly red and blue light from the spectrum and reflects green light — which is why leaves appear green to us 🌱.
Power Draw: Watt (W) vs Kilowatt-Hour (kWh)
Power draw describes the electrical power consumption in watts (W). When paying for electricity you pay for the energy you've used. Energy is generally measured in kilowatt-hours (kWh).
How much light a lamp makes of the power it draws is described by its PPE, and how much of that light your plants get by the system efficacy.
PPE: Photosynthetic Photon Efficacy (µmol/J)
Photosynthetic photon efficacy (PPE) is measured in µmol/J. It describes a grow light's output in the PAR spectrum (µmol/s) per watt (W = J/s) of electricity used. The higher the PPE, the less you spend on electricity for the same yield.
The PPE counts all the light a lamp emits, no matter where it ends up. The system efficacy only counts the light that reaches your plants.
PPF: Photosynthetic Photon Flux (µmol/s)
Photosynthetic photon flux (PPF) is measured in µmol/s. It describes the total output of a light source within the PAR spectrum. While the PPF of a lamp
stays the same, the PPFD increases the closer a surface is in respect to the light source. The PPF changes only, if its power intake is modified (e.g.
by
dimming) or the light's efficiency changes (e.g. due to aging).
The synonym in lighting for humans would be luminous flux (lumen).
Read
this detailed article to learn more about the different perception of light between plants and humans.
The PPF on a lamp's spec sheet (its rated PPF) is all the light it emits. Only a part of it reaches your plants: the usable PPF. How large that part is, is described by the CU.
PPFD: Photosynthetic Photon Flux Density (µmol/m²/s)
The intensity of PAR reaching a surface, such as plant leaves, is quantified as photosynthetic photon flux density (PPFD). PPFD is typically measured in micromoles of photons per square meter per second (µmol/m²/s) *. This means that PPFD specifically measures the light available to plants for photosynthesis and thus, impacts their growth. It is therefore the most relevant measurement in plant lighting.
The synonym in lighting for humans would be illuminance. Read this detailed article to learn more about the different perceptions of light between plants and humans.
PPFD differs from spot to spot below a lamp. Averaged across the grow area, it is the light that reaches the area (the usable PPF) divided by the size of the area.
* ℹ️ You might stumble upon different representations of PPFD, however they're mathematically equal and mean exactly the same:
µmol/m²/s = µmol/s/m² = µmol/(m²·s) =
µmol·m-2·s-1
SMCF: Spectral Mismatch Correction Factor
Spectral mismatch correction (SMC) is a method used to compensate for the difference between a light meter's actual spectral responsivity and its ideal target responsivity. In practice, no sensor perfectly matches its target curve — a PAR meter will never have a perfectly flat response across 400–700 nm, and a lux meter will never perfectly replicate V(λ).
Since all known light sources have an uneven spectral distribution, these small deviations in sensor responsivity can lead to significant measurement errors, because the sensor over- or under-weights certain wavelengths relative to their true contribution.
The spectral mismatch correction factor (SMCF) is the numerical factor by which a raw meter reading must be multiplied to arrive at the true value. It is calculated by comparing the spectral power distribution (SPD) of the light source against the sensor's actual responsivity curve.
Crucially, the SMCF is unique to every combination of device, diffuser, light source, and measurement type. Which is why generic correction factor tables are rarely reliable.
This is why Photone requires you to select your light source when measuring. The correct SMCF is then calculated and applied automatically, using the default calibration for your device model, which is loaded the moment you open the app.
SPD: Spectral Power Distribution
A grow light's spectral power distribution (SPD) describes the ratio of the different wavelengths (or colors) that make up the light emitted. The chart below shows the SPD of a typical LED grow light. It shows a bump in the blue and red part of the spectrum – because these are the most important wavelengths that drive a plant's photosynthesis and thus its growth.
Spectral Responsivity
Spectral responsivity describes how sensitive a light meter's sensor is to different wavelengths of light. Crucially, that sensitivity is never uniform across the spectrum. To compensate for this, light meters use optical filters to shape the sensor's response to match a target responsivity curve.
Matching this target requires careful optical and electronic correction, something which cheaper sensors often fail to achieve accurately. This is why two light meters can give very different readings under the same grow light: their spectral responsivities differ, and some wavelengths are being over- or under-represented relative to their true contribution.
For lux meters, the target is the CIE photopic luminosity function V(λ) — the standard model of human eye sensitivity, which peaks around 555 nm. For plant lighting applications, the target is instead PAR(λ): a flat, equal response across all wavelengths from 400 to 700 nm (see this image).
The chart below illustrates this with three sensors at different price points. The PeakTech 5086 lux meter ($150), tuned to V(λ), lacks sensitivity in the blue and red parts of the spectrum — as expected for a lux meter. The LI-COR LI-190R PAR meter ($1,800) compensates for this, but would still require a spectral mismatch correction for a truly accurate reading. The UNI-T UT-383 ($40) falls into neither category: its responsivity is too broad to qualify as a lux meter, yet it still underperforms in the blue and red range and is thus a poor PAR meter.
System Efficacy (µmol/J)
The system efficacy tells how much light your plants get for every watt your lamp draws: the usable PPF divided by the power draw, in µmol/J.
It is the real-world counterpart of the PPE, which counts all the light a lamp emits, no matter where it ends up. As the system efficacy only counts the light that reaches the grow area, it is always lower: system efficacy = PPE × CU.
Uniformity (%)
Uniformity tells how evenly a grow light spreads its light across your grow area, in percent. At 100%, every spot would get the same PPFD.
Let's look at some example light footprints and compare their uniformity:
The footprint above shows a bad uniformity of 48%. While the center of this grow area gets 1164 µmol/m²/s, the corners less than 200. This could mean that the plants in the middle get more light than they can actually use, while those at the edges stay small.
Here we have a uniformity of 94%. Every spot gets between 532 and 652 µmol/m²/s, so all plants will grow equally.
To make your light more uniform, hang the lamp higher (more of its light may then miss your plants, see CU) or use several smaller lamps instead of one compact one.
💡 Don't like math? Create heatmaps like the ones above for free with the Photone app. It calculates the uniformity for you.
ℹ️ The uniformity takes every spot into account. How much light the darkest spot gets compared to the average is described by the min/avg ratio.
Usable PPF (µmol/s)
The usable PPF is the part of a grow light's PPF that actually reaches your grow area, measured in µmol/s. The spec sheet of a lamp states all the light it emits (its rated PPF). Whatever misses your plants is lost.
As it depends on your setup, you won't find the usable PPF on a spec sheet. To determine it, measure the PPFD at evenly spaced spots across your grow area, take the average and multiply it by the size of the area in m².
Divided by the rated PPF, the usable PPF gives the CU of your setup. Divided by the power draw of the lamp, it gives the system efficacy.
UV: Ultraviolet
Ultraviolet (UV) light describes electromagnetic radiation in wavelengths between 100 nm and 400 nm and is divided into three bands: UVA (315-400 nm), UVB (280-315 nm) and UVC (100-280 nm). Most UV light cannot be seen by the human eye.
VPD: Vapor Pressure Deficit
Measured in kilopascals (kPa), VPD describes how dry the air feels to a plant — how much more moisture the air could absorb before it's full. It depends on temperature and humidity together, which is why neither number means much on its own.
VPD controls transpiration: the plant pulling water up from its roots and releasing it through its leaves. That flow is how nutrients travel through the plant.
- VPD too low (air too humid): the plant can barely transpire. Nutrient uptake slows and mold risk rises.
- VPD too high (air too dry): the plant loses water faster than the roots can replace it, so it closes its pores. Closed pores means no CO₂ intake — and photosynthesis stops, no matter how much light you give it.
Typical targets: 0.4–0.8 kPa for seedlings, 0.8–1.2 kPa in veg, 1.2–1.6 kPa in flower.
VPD is the reason a high DLI alone won't get you a bigger harvest. Light sets the potential; climate decides whether the plant can use it.
Wavelength (nm)
What we know as “light” is actually electromagnetic radiation of different wavelengths that are visible to our eyes. The wavelength determines the light’s color. White (or natural) light consists of all colors of the rainbow combined 🌈.
Electromagnetic radiation (including light) travels in waves. The wavelength describes the distance between the repetition of these waves and thus, ultimately defines its color. The wavelength is a unit of distance and is measured in meters. Since visible light has a relatively short wavelength we use nanometers (nm), which is one billionth of a meter, as a common unit of measurement. Sometimes also micrometers (µm) or millimeters (mm) are used.
YPF: Yield Photon Flux (µmol/s)
Yield photon flux (YPF) measures the total light output of a light source weighted by the plant's light response defined by the McCree curve. The more common metric is photosynthetic photon flux (PPF) which weighs light equally at every wavelength.
YPFD: Yield Photon Flux Density (µmol/m²/s)
Yield photon flux density (YPF) measures light in micromoles per square meter per second (µmol/m²/s) weighted by the plant's light response defined by the McCree curve. The more common metric is PPFD which weighs light equally at every wavelength.
No results. Try something else ...
If you want to measure any of the above (or at least, what's most important: PPFD and DLI), we highly recommend our Grow Light Meter app. It allows you to quickly and easily measure PAR as PPFD, the daily light integral as well as calculate your plant's ideal lighting – and all of this on your phone or tablet. Photone is free to download on iOS and Android and may even save you hundreds of dollars otherwise unnecessarily spent on physical meters.
Still unclear? Or did we miss something? Simply reach out to us via the contact option. We hope this article helps you to understand more of the grow light science – and maybe even impress your friends at parties 🤓
Share This Article
Curious to learn more?
Join our free newsletter for the latest insights on plant lighting and updates from Photone.